




Tekniska specifikationer
Ethernet
LAN: 1 x LAN port, 10/100 Mbps, compliant with IEEE 802.3, IEEE 802.3u, 802.3az standards, supports auto MDI/MDIX cross-connect.
Network
Network protocols: TCP, UDP, IPv4, IPv6, ICMP, NTP, DNS, HTTP, HTTPS, SSL/TLS, ARP, SSH, DHCP, SNMP, MQTT
Connection Monitoring: Ping Reboot, Wget Reboot, Periodic Reboot
Network topology: Visual representation of your network showing which devices are connected to each other
DDNS: Support for over 25 service providers, others can be configured manually
Connection Monitoring: Ping Reboot, Wget Reboot, Periodic Reboot
Network topology: Visual representation of your network showing which devices are connected to each other
DDNS: Support for over 25 service providers, others can be configured manually
Security
Authentication: Pre-shared key, digital certificates, X.509 certificates, TACACS+, authentication of internal and external RADIUS users, IP and login attempt blocking, time-based login blocking, built-in random password generator
WEB filter: Blacklist to block unwanted websites, whitelist to allow only specified websites
Access Control: Flexible access control for SSH, web interface, CLI and Telnet
802.1x: Port-based network access control client
WEB filter: Blacklist to block unwanted websites, whitelist to allow only specified websites
Access Control: Flexible access control for SSH, web interface, CLI and Telnet
802.1x: Port-based network access control client
NTP
Supported modes: Server – Receives time from GPS and acts as an NTP server to broadcast time to other devices (Stratum 1). Broadcasts time via UDP or over serial (RS232, RS485)
Daytime protocol: TCP/UDP
Data over serial: RS232/RS485
NTP: NTPv4, NTP authentication (MD5/SHA1), Unicast/Multicast/Broadcast mode
Protocol: NTP Stratum 1 time server (NTPv4)
NTP accuracy: Ethernet NTP ±1 ms total
NTP performance: 300 NTP requests per second (wire speed)
Sync Accuracy: LAN sync typically 1-10ms
Daytime protocol: TCP/UDP
Data over serial: RS232/RS485
NTP: NTPv4, NTP authentication (MD5/SHA1), Unicast/Multicast/Broadcast mode
Protocol: NTP Stratum 1 time server (NTPv4)
NTP accuracy: Ethernet NTP ±1 ms total
NTP performance: 300 NTP requests per second (wire speed)
Sync Accuracy: LAN sync typically 1-10ms
Modbus
Supported modes: Server, Client
Supported connection types: RTU (RS232, RS485), TCP
Custom registers: MODBUS TCP custom register block requests, which read/write to a file in the router and can be used to extend the functionality of the MODBUS TCP client
Supported data formats: 8-bit: INT, UINT; 16-bit: INT, UINT (MSB or LSB first); 32-bit: float, INT, UINT (ABCD (big-endian), DCBA (little-endian), CDAB, BADC), HEX, ASCII
Supported connection types: RTU (RS232, RS485), TCP
Custom registers: MODBUS TCP custom register block requests, which read/write to a file in the router and can be used to extend the functionality of the MODBUS TCP client
Supported data formats: 8-bit: INT, UINT; 16-bit: INT, UINT (MSB or LSB first); 32-bit: float, INT, UINT (ABCD (big-endian), DCBA (little-endian), CDAB, BADC), HEX, ASCII
MQTT Gateway
Modbus MQTT Gateway: Enables sending commands and receiving data from MODBUS server via MQTT broker.
API
Teltonika Networks Web API (beta) support: Extend your device's capabilities by using a set of configurable API endpoints to retrieve or modify data. For more information, see this documentation: https://developers.teltonika-networks.com
Monitoring
WEB UI: HTTP/HTTPS, status, configuration, firmware update, CLI, troubleshooting, multiple event log servers, firmware update notifications, event logs, system logs, kernel logs, internet status
SSH: SSH (v1, v2)
SNMP: SNMP (v1, v2, v3), SNMP Trap, protection against brute force attacks
JSON-RPC: Management API over HTTP/HTTPS
MODBUS: MODBUS TCP status/control
SSH: SSH (v1, v2)
SNMP: SNMP (v1, v2, v3), SNMP Trap, protection against brute force attacks
JSON-RPC: Management API over HTTP/HTTPS
MODBUS: MODBUS TCP status/control
System properties
CPU: Mediatek, 580 MHz, MIPS 24KEc
RAM: 128MB, DDR2
FLASH storage: 16 MB, NOR Flash
RAM: 128MB, DDR2
FLASH storage: 16 MB, NOR Flash
Firmware configuration
WEB UI: Update firmware from file, check firmware on server, configuration profiles, configuration backup
Keep settings: Update firmware without losing current configuration
Factory Reset: A full factory reset will restore all system settings, including IP address, PIN, and user data to the manufacturer's default configuration.
Keep settings: Update firmware without losing current configuration
Factory Reset: A full factory reset will restore all system settings, including IP address, PIN, and user data to the manufacturer's default configuration.
Firmware customization
Operating system: RutOS (OpenWrt-based Linux OS)
Supported languages: Busybox shell (ash), Lua 5.1, C, C++
Development tools: SDK package with build environment provided
GPL Customization: You can create your own custom, branded firmware and web application by changing colors, logos, and other elements of our firmware to suit your or your customers' needs
Supported languages: Busybox shell (ash), Lua 5.1, C, C++
Development tools: SDK package with build environment provided
GPL Customization: You can create your own custom, branded firmware and web application by changing colors, logos, and other elements of our firmware to suit your or your customers' needs
Location follow-up
GNSS: GPS, GLONASS, BeiDou, Galileo and QZSS
Receive sensitivity: Receive sensitivity at connection -146 dBm, reconnect sensitivity -157 dBm, tracking sensitivity -157 dBm
Accuracy: CEP-50 under free line of sight 2.5 m
Time source: GPS 1575.42 ±1.023 MHz, GLONASS 1597.5-1605.8 MHz, Galileo 1575.42 ±2.046 MHz, BDS 1561.098 ±2.046 MHz
Start-up time: Cold GPS connection in less than 120 seconds
Receive sensitivity: Receive sensitivity at connection -146 dBm, reconnect sensitivity -157 dBm, tracking sensitivity -157 dBm
Accuracy: CEP-50 under free line of sight 2.5 m
Time source: GPS 1575.42 ±1.023 MHz, GLONASS 1597.5-1605.8 MHz, Galileo 1575.42 ±2.046 MHz, BDS 1561.098 ±2.046 MHz
Start-up time: Cold GPS connection in less than 120 seconds
Serial
RS232: Terminal block connector: TX, RX, RTS, CTS
RS485: Terminal block connector: D+, D-, R+, R- (2- or 4-wire interface)
RS485: Terminal block connector: D+, D-, R+, R- (2- or 4-wire interface)
Input/Output
Input: 3 x digital input, 0–6 V detected as logic low, 8–30 V detected as logic high
Output: 3 x digital output, open collector, max output 30 V, 300 mA
Output: 3 x digital output, open collector, max output 30 V, 300 mA
Current
Connector: 2-pin in 16-pin industrial terminal block
Input voltage range: 9–30 VDC, overvoltage protection, reverse polarity protection, surge protection +/- 1 kV 50 µs max
Power consumption: Sleep: < 2 W, Max: < 3.5 W
Input voltage range: 9–30 VDC, overvoltage protection, reverse polarity protection, surge protection +/- 1 kV 50 µs max
Power consumption: Sleep: < 2 W, Max: < 3.5 W
Physical interfaces
Ethernet: 1 x RJ45 port, 10/100 Mbps
I/O: 3 x configurable I/O, 1 x analog input in 16-pin terminal block
Status LEDs: 1 x Power, 2 x GNSS Status LEDs, 1 x NTP Server Status LED, 3 x I/O Status LEDs
Power: 1 x 16-pin terminal block
Antenna: 1 x SMA for GNSS
RS232: 4-pin in 16-pin terminal block (TX, RX, RTS, CTS)
RS485: 4-pin in 16-pin terminal block (D+, D-, R+, R-)
Reset: Restart / User settings reset / Factory reset button
I/O: 3 x configurable I/O, 1 x analog input in 16-pin terminal block
Status LEDs: 1 x Power, 2 x GNSS Status LEDs, 1 x NTP Server Status LED, 3 x I/O Status LEDs
Power: 1 x 16-pin terminal block
Antenna: 1 x SMA for GNSS
RS232: 4-pin in 16-pin terminal block (TX, RX, RTS, CTS)
RS485: 4-pin in 16-pin terminal block (D+, D-, R+, R-)
Reset: Restart / User settings reset / Factory reset button
Physical specifications
Housing material: Anodized aluminum housing and panels
Dimensions (W x H x D): 82.6 x 25 x 83 mm
Weight: 180g
Mounting options: DIN rail, wall mount, flat surface (all require additional kit)
Dimensions (W x H x D): 82.6 x 25 x 83 mm
Weight: 180g
Mounting options: DIN rail, wall mount, flat surface (all require additional kit)
Operating area
Operating temperature: -40°C to 75°C
Operating humidity: 10% to 90% non-condensing
Protection class: IP30
Operating humidity: 10% to 90% non-condensing
Protection class: IP30
Regulations & Type Approval
Regulation: CE, UKCA, CB, UCRF, EAC, WEEE
Garanti
2 års fabriksgaranti

Network synchronization without the need for internet

Access to many connections

Security for total control

Easy installation to get started quickly

Do you want to know more about the product?
Contact us for a demo or if you have any questions.